Surgical & Implant Kits

Sinus lift and sinus graft instruments, bone-compression kits and drill kits, each described here by what is in the set and the case it comes in. Two ten-piece osteotome sets, the concave-tip osteotome set and the convex-tip set, each hold five straight and five offset instruments in a leather pouch. A five-piece set of double-ended instruments, with titanium plasma-coated working ends and 9 mm handles, completes the hand instruments.

The bone-compression kits differ in their screws, drills and case. The 12-piece kit, in a fitted stainless steel case, and the kit with saw disks in a sterilisation cassette each carry five expansion screws from 2.6 mm to 4.3 mm, and the saw-disk kit adds two saw disks of 7.0 mm and 10.0 mm. The bone compression screw kit holds seven graduated screws in a fitted stainless steel case, and the 17-piece kit holds six irrigated twist drills from 2.0 mm to 5.20 mm in a sterilisation cassette.

For drilling, the 8-piece trephine drill kit runs from 3 mm to 10 mm in a stainless steel sterilisation case, and the 8-piece dental twist drill kit holds eight drills in a stainless steel holder. Two bench pieces sit with them: a 30 mm stainless steel mixing well for amalgam or bone, and a hardwood bur block with 88 holes for 1/8 inch shanks. The guides below the range explain osteotome tips, trephine drills and what goes into a sinus-lift and bone-compression kit.

Skip to results list

Active filters:

11 items
Column grid
Column grid

Filter

Active filters:

Common questions

Should I buy straight or offset sinus lift osteotomes?

Straight shafts transmit force in line and suit anterior sites with open access. Offset shafts step the working end around the buccal corridor, which is where they earn their place in the posterior maxilla. A full set carries both, pairing each diameter in straight and offset configurations.

What is the difference between concave and convex osteotome tips?

Concave, cupped tips capture and carry bone ahead of the instrument, the classic Summers approach for lifting the membrane with a graft cushion. Convex tips compact laterally as they advance, condensing softer bone to improve primary stability, so a convex set is the condensing counterpart to a concave set.

Which trephine drill size do I need for bone harvesting?

Trephines come in graded diameters so the core size matches the task. A fine-stepped eight-piece set covering 2 to 5.5 mm suits smaller cores, while a larger 3 to 10 mm kit covers bigger harvests. Trephining generates heat, so copious irrigation and controlled speed are essential.